Simulation of Broken Conductor in Distribution Network by ATP-EMTP Program
Pacula, Václav ; Novotný, Jan (referee) ; Paar, Martin (advisor)
When broken conductor will impact on the ground. In isolated networks to ground fault occurs. For fault detection is the most commonly used method of zero-sequence voltage. The principle of the method is the sum of the voltage in all phases in the symmetric systém is the sum zero. The aim is to compare this method with the method of symmetrical sequence method and timeshiftomg. The method of symmetrical sequences compares sequency currents. To change the status of the systemis changed period, this method is based on the time shift.For comparison is used the ATP-EMTP program, that simulates the electrical transients. In this program are designed network model in which, these methods are investigated. It is a simple model of an idealized model and part of distribution network. After the simulation waveforms of events are processed and the results found faultdetection. Protection used today are based on measurements of zero-sequence voltage. A newer method of protection that extends further the possibility of detection and localization.
Short Circuit Calculation of MV Grid
Knápková, Dagmar ; Topolánek, David (referee) ; Toman, Petr (advisor)
This bachelor’s thesis deals with the faults in the distribution networks, focusing on shortcircuits as the most common and the most signiĄcant types of faults. The thesis is divided into theoretical and practical part. In the theoretical introduction, describes the types of faults in distribution networks with a focus on the short-circiuts, their causes, and the impact on distribution networks. Follows a description of the time course of short-circuit currents, short-circuit calculation simpliĄcation assumptions, the formula for calculating the impedance of the various elements of the short-circuits schema and the calculation methods of short-circuit currents in accordance with ČSN EN 60909-0. In the practical part, there is an example of the calculation of simple network conĄguration. Follows an analysis of the real network, including the analysis of the method of operation and the selection of appropriate method for the calculation of the short-circuit. After that are carried out practical calculations short-circuit conditions in four places on the network, and three diferent types of short circuits. For one-phase short-circuit is subsequently carried out the distribution of currents in a parallel branch of the distribution lines. At the conclusion of the bachelor’s thesis is caried out evaluation the results and analysis of the data obtained by calculation.
Testing of Directional Earth Fault Protections Using The Experimentally Obtained Fault Records
Holub, Martin ; Topolánek, David (referee) ; Orságová, Jaroslava (advisor)
Master thesis Testing of Directional Earth Fault Protections Using the Experimentally Obtained Fault Records deals with the protective functions of earth fault protections during earth faults in compensated medium voltage distribution network and their testing options. At the beginning of the thesis we charakterize operation of medium voltage distribution system in general. We begin with definition and characteristics of earth fault and its compartmentalization by the type of the fault, size of the transition resistance and duration. We also mention grounding methods of node winding transformer on medium voltage distribution network and we describe the most common of them in detail, i.e. network grouded through the arc suppression coil and its operation with automatic switching auxiliary resistor. In this part of the thesis we discuss the localization of the earth fault using passive static methods in compensated systems, which include wattmetric, admittance and conductance method. In next section we deal with the fault records stored in COMTRADE file format, its structure and all elements of its configuration and data file. We create and describe an example of converting ADF file format, recorded by Yokogawa oscilloscope fault recorder, into COMTRADE file format using Microsoft Excel program and M-File created in the MATLAB program. In the practical part we introduce workspace devices and software, which includes secondary testing equipment OMICRON CMC 256plus and its software OMICRON Test Universe with Advance Transplay test module, we further describe multifunctional earth fault protection RYo from PROTECTION & CONSULTING, s. r. o. and machine terminal REM 543 from ABB and their protective functions. The last part describes the actual testing of parallel connected earth fault protection with COMTRADE fault records by Advance Transplay test module in the OMICRON Test Universe. In the conclusion we describe evaluation of the suitability of each protective functions of earth fault protection in a variety of sizes the transition resistance at the earth fault location.
Contactless Fault Indicator for MV Lines
Pernica, Drahomír ; Mišurec, Jiří (referee) ; Mišák,, Stanislav (referee) ; Toman, Petr (advisor)
The theoretical findings about methods of earth faults indication are elaborated in this thesis into form, which is applicable to design contactless indicator of failure states on MV lines. This design contains electromagnetic field sensors, evaluation device and software support. The higher effectiveness of clearing of fault and better health and asset protection is supposed by using of these indicators.
Earth fault relay testing
Herůfek, Radek ; Topolánek, David (referee) ; Orságová, Jaroslava (advisor)
Bachelor thesis deals with an earth fault relay in compensated medium voltage distribution network. At the beginning of the thesis is described the method of operation compensated system and its advantages and disadvantages of using it. In addition, there is explained the definition of the ground fault, its types and there is outlined the method of solution asymmetrical single-phase fault. Thoroughly there is characterized distribution of voltages and currents, which is important for determination of affected and unaffected outlet. Among others, there is described the mode of action the arc suppression coil on caused fault current and also there are presented the auxiliary systems automation. In the next part the basic requirements for protections and its basic kinds are described. Finally the theoretical part describes principle of the earth fault relays and is presented means and methods used for indicate an affected outlet and earth fault localization. In the practical part, follows more detailed description of the protection REM 543 and testing equipment OMICRON CMC 256 +. In addition, there is explained connection process and setting selected functions and modules for testing earth fault relay. Assessment of generated and played transient disturbance records at the end.
Development of the tool for application of the method for localization of unsymmetrical faults
Pospíšil, Tomáš ; Vyčítal, Václav (referee) ; Topolánek, David (advisor)
In resonant earthed distribution systems, the capacitive current of the system is compensated by grounding via a arc suppression coil. The level of fault current is then very small and independent on the fault location which greatly complicates the rapid finding of the fault site. At this moment there is no method to be used to directly locate the site of a single-phase fault in the distribution network, new methods and solutions are being constantly sought to address the shortcomings of the existent localization methods. The diploma thesis deals with the design of a universal software tool that allows to apply a new method of locating an asymmetric fault in the distribution network. The tool is created in a MATLAB environment and utilizes the negative sequence voltage measured on the low-voltage sides of the distribution transformers and the negative sequence current measured behind the power transformer. By using the proposed tool, it is possible to read the parameters of any part of the distribution system that the user enters together with the measured values of the voltage and current into the initialization file. After the specified network parameters are loaded, a numerical model is created, which is then used for the method. In the work is described in detail the way of entering the parameters of the network into the initialization file, the method of automatic assembling of the numerical model based on the entered data and the possibility of customizing the calculation parameters. At the end of the thesis, the functionality of the proposed software tool is verified on data from simulation of the test network.
Testing of the admitance principle of the fault indicator
Musil, Milan ; Vyčítal, Václav (referee) ; Topolánek, David (advisor)
The thesis deals with the proposal, implementation and evaluation of test for fault condition indicators. Thesis focusing on earth fault indicators based on admittance principles. These indicators must be able to evaluate earth faults in compensated, compensated with auxiliary resistor, unearthed and high-resistance earthed networks. The proposed tests verify the current and voltage measurement errors in inputs including monitored characteristic variables such as conductance and susceptance. The proposed test are applied to a selected ample of the fault indicator. As part of the tests, the indicator is subjected to secondary test using the Omicron CMC256plus tester as well as test on fault records that have been converted to COMTRADE for this purpose. The last series of tests carried out uses the physical model of the medium voltage system, where the tested equipment is subjected to fault states in the compensated whit auxiliary resistor system and isolated system. Furthermore, part of the thesis is research of new methods of earth fault detection, including their principles and function description. Also included in the thesis is an overview of manufacturers of indicators, or protection, who are involved in the production of earth fault protection.
Calculation of characteristic values of the earth fault in MV network.
Písařovic, Antonín ; Orságová, Jaroslava (referee) ; Toman, Petr (advisor)
In the bachelor thesis author deals with the earth fault in MV network. In the theoretical part of thesis there are identified existing faults occuring on power lines. The pivotal point of thesis is the analysis of the earth fault in network with ineffectively earthead node. In the parctical part author calculates the total capacity of specific network and according to the obtained results he proposes the suitable arc suppresion coil to reduce the earth current.
Generating of the fault record for protection and fault indicator testing
Bažata, Petr ; Jinderle, Pavel (referee) ; Topolánek, David (advisor)
The thesis is focused on a presentation of a model creating which is followed by the simulation of running real network with using the compensatory elements to minimize the incurred failures. This thesis is divided into two thematic parts – the first theoretical one deals with the basis structuring of short-circuit faults and more detailed study of ineffective ground connection. Particularly this part attends to the problematic of a network description with extinguishing suppression. Using the compensation minimizes the impact of the failure state. A short-term fixing of a resistor improves the function of the ground-fault protection and helps to detect the outgoing section damaged by the defect. Furthermore the thesis indicates simulation programs, compares them and chooses the most suitable one for the next practical part. This is focused on a simulation of a real network run, together with elements for an effective defect-reduction or easier detection of ground connection. As a simulation of a ground short-circuit is the model in the end of the thesis modified on a network with an effective grounded bundle. Testing of the model correctness and creating a record of a model using the real ground protection settings is also one part of this thesis.
Ground Fault Location in Compensated Distribution Network
Topolánek, David ; Janíček,, František (referee) ; Mišák,, Stanislav (referee) ; Toman, Petr (advisor)
The most widespread system of an earthing neutral point of a supply transformer in a MV network is an earthing through an arc-suppression coil. In this case of a resonant-earthed power system a fault current is compensated by the suppression coil and only residual current flows through a fault point. A value of the residual current is much smaller then a value of an original capacitive current of the network and is not dependent on the fault location. According to that reasons it is really complicated to fast and accurately determine the fault point location. Since nowadays used methods for the ground fault location inside wide distribution networks have a lot of disadvantages, the thesis is focused on a proposal of a new method for the ground fault location especially inside of a compensated network. The main reasons for a consecutive installation of power quality meters into distribution transformer substations are a power quality monitoring and a global evolution of an electrical network onto the “SmartGrids”. In case that all results from the meters are properly synchronized and centralized, new possibilities of control or of an evaluation of a network are enabled. This doctoral thesis proposes the possibility for the ground fault detection with an aid of synchronized records recorded on the low-voltage side of the distribution transformers 22/0.4 kV into the network equipped with automatics for short-time increasing of an active part of a faulty current. The described method uses a voltage drop evoked by connecting of the auxiliary resistor for location of the faulty section. The proposed method is tested with help of numerical model which presents a part of the distribution network Series of simulation are executed and correct function and force function of the method is reviewed. Finally the thesis describes real experiment and also a confrontation between simulation and real measuring, and also possibilities of method usage are commented.